75C9h
CLAAS 75C9h – Claas Tr1 A57 1 Transmission Module: Reverse Gear Solenoid Valve Return Current Below Setpoint
Issue description
The actual current measured on the reverse gear solenoid valve return is less than the setpoint value. This may trigger an audio warning and request an
Check the cause
For a possible open circuit in the solenoid valve supply harness
For a possible short circuit to earth on the solenoid valve
The resistance of the solenoid valve winding
Repair steps
Check the solenoid valve supply harness for an open circuit
Check the solenoid valve for a short circuit to earth
Measure the resistance of the solenoid valve winding
Use the “Auto 5” module with tool number 60 05 033 249
Change the component if required according to the service manual