CLAAS 75D2h – Claas Tr1 A57 1 Transmission Module: Inconsistency Between Crawler Range Engaging Contact and Mechanical Status
Issue description
There is an inconsistency between the information from the crawler range engaging contact and the mechanical status of the crawler range. This may affect the REH (A58) lifting module and its associated functions. The issue may be related to the theoretical speed sensor, the slow range contact, or the status of the crawler range or range module.
Check the cause
The theoretical speed sensor (B227)
The slow range contact (Z150)
Status of the crawler range
Status of the range module
The 'Auto 5' module using tool n° 60 05 033 249
Repair steps
Check
The theoretical speed sensor (B227) for proper function and connection.
Check
The slow range contact (Z150) for proper function and connection.
Check
The status of the crawler range and the range module for any signs of malfunction.
Use
The 'Auto 5' module using tool n° 60 05 033 249 to diagnose and, if required, change the module.
Parts you might need
(0)Get help to fix this fault by requesting a quote