75D8h

CLAAS 75D8h – Claas Tr1 A57 1 Transmission Module: Range Sensors Simultaneously Open

Issue description

The system detects that a minimum of two range sensors are simultaneously open, which is not normal as only one should be open at a time. This may indicate a fault in the range engagement contacts or a mechanical issue with the range module.

Check the cause

  1. The A range engaged contact (Z153-1)

  2. The B range engaged contact (Z153-2)

  3. The C range engaged contact (Z153-3)

  4. The D range engaged contact (Z153-4)

  5. Possible mechanical problem on the range module

Repair steps

  1. Inspect

    Inspect the A range engaged contact (Z153-1) for damage or improper connection.

  2. Inspect

    Inspect the B range engaged contact (Z153-2) for damage or improper connection.

  3. Inspect

    Inspect the C range engaged contact (Z153-3) for damage or improper connection.

  4. Inspect

    Inspect the D range engaged contact (Z153-4) for damage or improper connection.

  5. Investigate

    Investigate the range module for possible mechanical issues that could cause multiple sensors to activate simultaneously.