CLAAS 75DCh – Claas Tr1 A57 1 Transmission Module: Issue with Saving Parameters During Standby Mode
Issue description
The system is experiencing a problem with saving parameters when placing units on standby. The cause may be related to a loss of the permanent 12 V supply before the 12 V shutoff after switching on the ignition. The system may require adjustment of the 'Auto 5' setting.
Check the cause
The permanent 12 V supply before ignition is turned on
The 'Auto 5' setting in the system configuration
Repair steps
Verify the 12 V supply
Check for a loss of the permanent 12 V supply prior to 12 V shutoff after switching on the ignition.
Adjust the 'Auto 5' setting
If the 12 V supply is stable, modify the 'Auto 5' setting as required.
Parts you might need