75DDh

CLAAS 75DDh – Claas Tr1 A57 1 Transmission Module: Low 12 V Supply Voltage After Ignition Activation

Issue description

The 12 V supply voltage is below 7 V when the ignition is turned on. This may affect the operation of the system. The issue is related to the power supply and connections.

Check the cause

  1. The battery voltage

  2. The 12V harnesses and connections after contact of the 'Auto 5' modules

Repair steps

  1. Check

    The battery voltage to ensure it meets the required specifications.

  2. Inspect

    The 12V harnesses and connections after contact of the 'Auto 5' modules for any damage, looseness, or corrosion.

Parts you might need

(0)