CLAAS 75DEh – Claas Tr1 A57 1 Transmission Module: 10 V Supply to Sensors Out of Tolerance
Issue description
The 10 V supply to the sensors is not within the ± 5% tolerance. This may be caused by a short circuit in the harnesses or sensors, or an issue with the connections. The affected circuit should be checked for faults.
Check the cause
The harnesses and their connections
The sensors for possible short circuits
The “Auto 5” module using tool n° 60 05 033 249
Repair steps
Check for a possible short circuit
Inspect the harnesses and sensors for signs of a short circuit.
Inspect the harnesses and their connections
Ensure all connections are secure and free from damage.
Use the specified tool to check the “Auto 5” module
Use tool n° 60 05 033 249 to test the “Auto 5” module and replace it if necessary.
Parts you might need