CLAAS 75DEh – TR1: TR1 10V Supply Out of Tolerance
Issue description
The 10-volt power supply originating from the TR1 (A57-1) transmission module is operating outside its specified tolerance of ±5%. This voltage deviation can lead to incorrect sensor readings or sensor malfunction, which may affect proper operation of transmission functions such as Revershift, clutch pedal position, and robotized range shifting.
Applies to these machines
13 machines- Axion 810
- Axion 820
- Axion 830
- Axion 840
- Axion 850
- Arion 510
- Arion 530
- Arion 550
- Arion 620
- Arion 640
- Arion 650
- Arion 410
- Arion 430
Check the cause
Ensure adequate battery voltage and check the main 12V supplies and fuses for the control modules
Inspect the wiring harnesses and sensors connected to the TR1 module for any signs of a short circuit
Thoroughly inspect all electrical harnesses and connectors associated with the TR1 (A57-1) module for damage, corrosion, or loose connections
Repair steps
Inspect wiring and sensors
Perform the diagnostic checks to identify any short circuits, wiring faults, or sensor failures.
Test TR1 module
If the harnesses and sensors are in good condition, use the specific CLAAS diagnostic tool (part number 60 05 033 249) to test the 'Auto 5' / TR1 (A57-1) module.
Replace TR1 module
If the module is determined to be faulty after testing, replace the Transmission Control Module.
Parts you might need
(5)Transmission Control Module TR1 / Auto 5 Module
Use CLAAS Parts Doc online catalog with machine serial number to obtain correct OEM part number
Diagnostic tool
60 05 033 249Specific tool required to test the Auto 5 module
"Auto 5" input/output control harness
60 0570 630 6Diagnostic tool harness.
Transmission Speed Sensor
011799Specific part depends on the failed sensor.
- Angle Sensor0000117801
Specific part depends on the failed sensor.
Get help to fix this fault by requesting a quote