75DEh
CLAAS 75DEh: TR1 (A57-1) 10 V supply to the sensors is not within the ± 5 % tolerance
Issue description
The 10 V supply to the sensors is outside the acceptable tolerance range of ± 5 %, which may affect the proper operation of the sensors.
Check the cause
The power supply to the sensors
The wiring and connections to the sensors
The voltage output at the sensor terminals
Repair steps
Verify the voltage supply
Use a multimeter to measure the voltage at the sensor power supply and confirm it is within the 10 V ± 5 % range.
Inspect wiring and connections
Check for loose, damaged, or corroded wiring and connections related to the sensor power supply.
Test the sensor power circuit
If the voltage is out of range, test the circuit for faults or damage that may be causing the issue.