Id75E2h / 75E2h (335)

CLAAS Id75E2h / 75E2h (335) – TR1 (A57-1) Transmission Module: Short circuit or open circuit on range D solenoid valve (SVD)

Issue description

The transmission control system has detected an electrical fault (either a broken connection or a short) in the circuit responsible for actuating the Range D synchronizer in the robotized gearbox.

Applies to these machines

  • CLAAS Axion 800 Series (e.g., 810, 850)
  • CLAAS Arion 600/500 Series (e.g., 510, 610, 630, 640, 650)
  • CLAAS Arion 400 Series (e.g., 410, 420, 430)

Check the cause

  1. Check the connectors and continuity of the harnesses linking the TR1 module to the Range D solenoid valve (Y339-4)

  2. Inspect the wiring specifically for any short-circuits to ground, short-circuits to 12V, or open circuits

  3. Check the internal resistance of the Range D solenoid valve (Y339-4)

  4. Check the sources of energy (fuses, 12V supply, and ground connections)

  5. Test the Auto 5 electronic control unit using the official CLAAS diagnostic tool/harness (Tool No. 60 05 033 249) to rule out an internal module failure

Repair steps

  1. Read and Record

    Note all error codes present on the tractor. Analyze interactions, as one code can generate another.

  2. Access the Solenoid

    Locate the transmission hydraulic control block. The gearbox has 4 synchronized ranges (A, B, C, D) controlled electrohydraulically by ON/OFF solenoid valves. Locate the Range D solenoid valve (Y339-4).

  3. Inspect Wiring

    Disconnect the harness at the Y339-4 solenoid and at the TR1 (A57-1) module. Perform a continuity and short-to-ground test on the wires. Repair or replace the harness if damaged.

  4. Test/Replace Solenoid

    If the wiring is intact, test the solenoid coil's resistance. If it is out of specification (open or shorted internally), replace the Range D solenoid valve.

  5. Test/Replace Auto 5 Module

    If the solenoid and wiring are both good, the fault likely lies within the Auto 5 module. Connect the Auto 5 input/output control harness (Tool 60 05 033 249) to verify module outputs. If the module is faulty, replace it. Note: Replacement modules must be calibrated/programmed to the tractor.

  6. Clear and Test

    Clear all error codes from the TR1 module and test drive the tractor through all ranges to ensure the anomaly does not reappear.

Parts you might need

(6)
  • Range D Solenoid Valve (SVD)

    Y339-4

    Generic Name: Transmission Range D Solenoid Valve / Synchronizer Coil. Often listed alongside Y309 depending on the specific transmission block diagram.

  • Auto 5 Control Module (TR1 / A57-1)

    9013500M1

    AGCO/CLAAS cross-reference number. Often referred to as the 'Auto 5 DUAL-CAN' control unit. Highly sensitive to moisture/water damage. Must be taught/calibrated to the specific tractor's functions.

  • Auto 5 Control Module (TR1 / A57-1)

    4301386M94

    AGCO/CLAAS cross-reference number.

  • Auto 5 Control Module (TR1 / A57-1)

    3712731M94

    AGCO/CLAAS cross-reference number.

  • Auto 5 Control Module (TR1 / A57-1)

    4313982M1

    AGCO/CLAAS cross-reference number.

  • Diagnostic Tool

    60 05 033 249

    Auto 5 input/output control harness.

Get help to fix this fault by requesting a quote

Browse other CLAAS codes