CLAAS 75E2h – TR1: Range D Solenoid Valve Circuit Fault
Issue description
The transmission control module has detected an electrical fault in the circuit for the solenoid valve that controls range D of the transmission. This fault can be either a short circuit (current taking an unintended path) or an open circuit (interrupted current path). This condition will affect the tractor's ability to engage or disengage range D and typically triggers an audio warning.
Applies to these machines
12 machines- Axion 810
- Axion 850
- Arion 410
- Arion 430
- Arion 510
- Arion 530
- Arion 550
- Arion 610
- Arion 620
- Arion 630
- Arion 640
- Arion 650
Check the cause
Visually inspect the wiring harness and connectors between the TR1 (A57-1) control module and the range D solenoid valve (Y339-4) for damage, corrosion, or loose connections.
Check for an open circuit: disconnect the harness and use a multimeter to check for continuity on the wire from terminal 10 of the TR1 module connector to the solenoid valve connector (infinite resistance indicates a break).
Check for a short circuit to ground: with the harness disconnected, measure resistance between the signal wire (terminal 10) and chassis ground. A low resistance reading indicates a short circuit to ground.
Check solenoid valve resistance: measure across the two terminals of the solenoid valve (Y339-4). Infinite resistance indicates an open coil, while very low resistance indicates an internal short.
Check power supply at the module: verify the TR1 module sends a 12V signal from terminal 10 to activate Range D (should be 0V when not engaged). Perform with caution to avoid module damage.
Repair steps
Repair wiring and connectors
If diagnostic checks reveal any damage to the wiring harness or connectors, repair or replace the affected sections. Ensure all connections are clean and secure.
Replace solenoid valve
If the solenoid valve (Y339-4) is found to be faulty (open coil, shorted, or out of specification), replace the component.
Test and replace TR1 module
If the wiring and solenoid valve are in good condition, test the TR1 (A57-1) 'Auto 5' module using special tool part number 60 05 033 249. Replace the module if it is determined to be faulty.
Clear codes and test operation
After completing repairs, clear all fault codes from the system using a compatible diagnostic tool. Operate the tractor to ensure the fault is resolved and the code does not reappear.
Parts you might need
(11)Range D Solenoid Valve (SVD) 1
Component ID Y339-4. Order via CLAAS dealer using this component ID.
Auto 5 Module Testing Tool
60 05 033 249Special tool required to test the TR1 (A57-1) control module.
Transmission Control Module TR1 (A57-1)
7700049277DApplicability of this part number varies by tractor model and year. Verify the correct part number using CLAAS Parts Doc or a dealer based on the machine's serial number.
Range D Solenoid Valve (SVD)
Y339-4Generic Name: Transmission Range D Solenoid Valve / Synchronizer Coil. Often listed alongside Y309 depending on the specific transmission block diagram.
Auto 5 Control Module (TR1 / A57-1)
9013500M1AGCO/CLAAS cross-reference number. Often referred to as the 'Auto 5 DUAL-CAN' control unit. Highly sensitive to moisture/water damage. Must be taught/calibrated to the specific tractor's functions.
Auto 5 Control Module (TR1 / A57-1)
4301386M94AGCO/CLAAS cross-reference number.
Auto 5 Control Module (TR1 / A57-1)
3712731M94AGCO/CLAAS cross-reference number.
Auto 5 Control Module (TR1 / A57-1)
4313982M1AGCO/CLAAS cross-reference number.
- Range D Solenoid Valve (SVD)0011367040
Also listed as 1136704. Listed for Arion and Axion models. Verify compatibility with serial number.
- Solenoid Valve0011620890
Alternative CLAAS solenoid valve. Verify compatibility with serial number.
- Solenoid Valve0000404430
Listed for various CLAAS models. Verify compatibility with serial number.