CLAAS 75E3h – Claas Tr1 A57 1 Transmission Module: Inconsistent 'Auto 5' Analog Readings
Issue description
The system is reporting inconsistent analog readings for 'Auto 5'. The cause may be related to a short circuit between the accelerator sensor harness and range sensor A, B, or between the clutch sensor harness and range sensor C, D. The 'Auto 5' module should be checked using tool n° 60 05 033 249, and replaced if necessary.
Check the cause
Possible short circuit between the accelerator sensor harness and range sensor A, B
Possible short circuit between the clutch sensor harness and range sensor C, D
The 'Auto 5' module using tool n° 60 05 033 249
Repair steps
Inspect
Check for a possible short circuit between the accelerator sensor harness and range sensor A, B.
Inspect
Check for a possible short circuit between the clutch sensor harness and range sensor C, D.
Test
Use tool n° 60 05 033 249 to check the 'Auto 5' module.
Replace
If the 'Auto 5' module is found to be faulty, replace it as required.
Parts you might need
(0)Get help to fix this fault by requesting a quote