CLAAS 7620h – Claas Tr2 A57 2 Transmission Module: Pressure of high-pressure brakes < 70 bar at initialisation
Issue description
The pressure of the high-pressure brakes is below 70 bar during initialisation. This is indicated by an audio warning and a steady brake indicator light. The issue may be related to the hydraulic circuit, braking pressure sensor, high pressure braking solenoid valve, or voltage delivered by the transformer.
Check the cause
The hydraulic circuit (valve, pipes, switch…)
Braking pressure sensor (B233)
High pressure braking solenoid valve (Y329)
Voltage delivered by the transformer (V24)
Repair steps
Check the hydraulic circuit
Inspect the valve, pipes, and switch for any issues that may affect the pressure of the high-pressure brakes.
Test the braking pressure sensor
Verify the functionality of the braking pressure sensor (B233) to ensure it is providing accurate readings.
Inspect the high pressure braking solenoid valve
Check the high pressure braking solenoid valve (Y329) for any faults or malfunctions.
Measure the voltage delivered by the transformer
Confirm that the transformer (V24) is delivering the correct voltage to the system.
Use the specified tool to check the “Auto 5” module
Use tool number 60 05 033 249 to check the “Auto 5” module and replace it if necessary.
Parts you might need
(0)Get help to fix this fault by requesting a quote