CLAAS 762Dh: Loss of ENG module engine speed information (module number 2)
Issue description
The system has detected a loss of engine speed information from the ENG module. This issue is associated with module number 2. An audio warning is triggered, but no ISC reset is requested.
Check the cause
The connection and wiring to the ENG module (module number 2)
The power supply to the ENG module (12V after ignition)
The signal integrity from the ENG module (module number 2) to the controller
Repair steps
Inspect the wiring and connections to the ENG module (module number 2)
Check for loose, damaged, or corroded connections.
Verify the power supply to the ENG module (module number 2)
Ensure that 12V is present after ignition.
Test the signal output from the ENG module (module number 2)
Use a diagnostic tool to confirm the signal is being transmitted correctly.
Parts you might need