7638h

CLAAS 7638h: TR2 (A57-2) Error on high pressure braking. The pressure sensor (B233) is disconnected Pump for 15 seconds. Start the tractor

Issue description

The system has detected an error related to high pressure braking, specifically a disconnection of the pressure sensor (B233). The pump has been inactive for 15 seconds. This issue may affect the proper operation of the braking system.

Check the cause

  1. The connection of the pressure sensor (B233)

  2. The condition of the pump

  3. The integrity of the wiring or circuit associated with the pressure sensor (B233)

Repair steps

  1. Inspect the pressure sensor (B233)

    Check for physical damage, loose connections, or corrosion on the pressure sensor (B233).

  2. Verify the pump operation

    Ensure the pump is functioning correctly and is properly connected to the system.

  3. Check the circuit for the pressure sensor (B233)

    Inspect the wiring and connections for any breaks, shorts, or poor contact.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes