7639h
CLAAS 7639h: TR2 (A57-2) Error on high pressure braking. Pressure < 70 bars during 0,2 to 2 seconds. Pump for 15 seconds. Start the tractor. Module number 2
Issue description
The system detects an issue with high pressure braking, where the pressure falls below 70 bars between 0.2 and 2 seconds. A pump runs for 15 seconds before the tractor starts. This issue is associated with module number 2.
Check the cause
The pressure sensor associated with module number 2
The circuit connected to module number 2
The pump operation during the 15-second interval
Repair steps
Inspect
Inspect the pressure sensor and its wiring for damage or loose connections.
Test
Test the circuit connected to module number 2 for proper functionality.
Verify
Verify the pump operation during the 15-second interval to ensure it is functioning as expected.
Parts you might need
(0)Get help to fix this fault by requesting a quote