Id763Ch / 763Ch (429)

CLAAS Id763Ch / 763Ch (429) – TR2 (A57-2) / Auto 5: Problem saving parameters when placing units on standby

Issue description

Occurs when the control unit fails to properly write and protect its specific parameters to the EEPROM memory during the shutdown/standby sequence.

Applies to these machines

  • Axion 800 series
  • Axion 850
  • Axion 900 series
  • Axion 950-920
  • Arion 600 series
  • Arion 610
  • Arion 630
  • Arion 640
  • Arion 400 series
  • Arion 410
  • Arion 430
  • Axos

Check the cause

  1. Check the 12V permanent supply for premature power loss prior to the standard 12V shutoff sequence after ignition is switched off

  2. Check battery voltage to ensure it is stable and not dropping below 7V during the shutdown/startup sequence

  3. Inspect wiring, connectors, and ground points linking the Auto 5 board to the battery to ensure the permanent power circuit is not interrupted prematurely

Repair steps

  1. Test the permanent 12V supply pin

    Test the permanent 12V supply pin on the TR2 (A57-2) Auto 5 module connector.

  2. Trace the wiring harness

    If power is being lost prematurely when the tractor is placed on standby, trace the wiring harness back to the battery/fuse panel to repair the open circuit or short.

  3. Check internal EEPROM

    If the 12V permanent supply is stable and functioning correctly, the internal EEPROM of the module has failed.

  4. Attempt to re-parameterize the Auto 5 module

    Attempt to re-parameterize the Auto 5 module using the CLAAS Diagnostic System (CDS / Win Metadiag©).

  5. Replace the Auto 5 module

    If the module will not accept or save the parameters, the 'Auto 5' module must be replaced. (Note: OEM documentation notes the use of CLAAS tool no. 60 05 033 249 for module replacement/programming).

Parts you might need

(7)
  • Auto 5 Electronic Control Unit / TR2 Transmission Module

    4301386M94

    AGCO/CLAAS OEM Auto 5 Module

  • Auto 5 Electronic Control Unit / TR2 Transmission Module

    9013500M1
  • Auto 5 Electronic Control Unit / TR2 Transmission Module

    9013501M1
  • Auto 5 Electronic Control Unit / TR2 Transmission Module

    3712731M94
  • Auto 5 Electronic Control Unit / TR2 Transmission Module

    4313982M1

    Dedicated replacement set with harness, which supersedes older controller 3715712M93

  • Auto 5 Electronic Control Unit / TR2 Transmission Module

    3715712M93

    Older controller superseded by 4313982M1

  • Auto 5 Electronic Control Unit / TR2 Transmission Module

    4 301 386 H93

    Auto 5 DC variant