763Dh
CLAAS 763Dh: TR2 (A57-2) Unit 12 V supply voltage is less than 7 V after switching on the ignition (component 2)
Issue description
The 12 V supply voltage for the unit is below 7 V immediately after the ignition is turned on. This may indicate a problem with the power supply or the component identified by this code.
Check the cause
The 12 V supply voltage to the unit
The connection and condition of the power supply wiring to component 2
The functionality of the unit itself
Repair steps
Check the 12 V supply voltage
Use a multimeter to measure the voltage at the power supply input of the unit.
Inspect the wiring and connections
Check for loose, damaged, or corroded wiring and connections related to the power supply of component 2.
Test the unit
If the voltage is correct, test the unit to determine if it is functioning properly.
Parts you might need
(0)Get help to fix this fault by requesting a quote