763Eh

CLAAS 763Eh – Claas Tr2 A57 2 Transmission Module: 10 V Supply to Sensors Out of Tolerance

Issue description

The 10 V supply to the sensors is not within the ± 5% tolerance. This may be caused by a short circuit in the harnesses or sensors. The affected circuit should be checked using the specified tool.

Check the cause

  1. The harnesses for possible short circuits

  2. The sensors for possible short circuits

  3. The 10 V supply to the sensors

Repair steps

  1. Check

    The harnesses for possible short circuits.

  2. Check

    The sensors for possible short circuits.

  3. Use

    The “Auto 5” module with tool n° 60 05 033 249 to diagnose and change if required.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes