CLAAS 7645h – Claas Tr2 A57 2 Transmission Module: Supply Voltage Measured on Solenoid Valve SV3 When Not Controlled

Issue description

A supply voltage is detected on solenoid valve SV3 when the driver is not controlled, indicated by a setpoint PWM of 0. This may trigger an audio warning and request an ISC reset. The issue may be caused by a 12 V short circuit on the solenoid valve power supply harness.

Check the cause

  1. Solenoid valve power supply harness for a 12 V short circuit

  2. The “Auto 5” module for potential faults

Repair steps

  1. Inspect

    Check the solenoid valve power supply harness for a 12 V short circuit.

  2. Use

    Use tool number 60 05 033 249 to check the “Auto 5” module.

  3. Replace

    Replace the “Auto 5” module if it is found to be faulty.

Parts you might need

(0)