CLAAS Id7647h / 7647h (440) – TR2 (A57-2): Current consumed by solenoid valve SV3 is greater than 1.4 A
Issue description
The current drawn by the transmission solenoid valve SV3 has surpassed the maximum permissible limit of 1.4 amps. This overcurrent condition triggers an audible alarm and necessitates an 'ISC' (Information System Control) reset. The underlying cause is typically an electrical fault, such as a short circuit in the wiring harness or an internal failure of the solenoid valve itself.
Applies to these machines
2 machines- Axion 850-810 series
- Arion 640-510 series
Check the cause
Check for a possible 12 V short circuit on the solenoid valve power supply harness
Check the solenoid valve SV3 (Component ID: Y335-3), identified as the Ratio under torque solenoid valve
Check the connectors and continuity of harnesses linking each component for short-circuits, open circuits, resistance, and energy sources (fuses, supply, and ground)
Check the 'Auto 5' module using CLAAS diagnostic tool n° 60 05 033 249
Repair steps
Document Codes
Note all error codes present on the tractor and analyze any interactions (as one error code can generate another).
Inspect Wiring
Visually and electrically inspect the power supply harness leading to solenoid valve SV3 (Y335-3) for a 12V short to power or ground. Repair any damaged wiring.
Test the Solenoid
Measure the resistance of the SV3 solenoid valve winding to ensure it is within specification and not internally shorted (which would cause the current draw to exceed 1.4 A). Replace the solenoid valve if it fails the resistance test.
Test the Control Module
If the wiring and solenoid are intact, use diagnostic tool n° 60 05 033 249 to test the "Auto 5" module.
Replace Components
Change the "Auto 5" module or the solenoid valve if required based on the test results.
Clear and Verify
Clear all error codes, then test drive the tractor to ensure the anomaly does not return.
Parts you might need
(8)Ratio under torque solenoid valve (SV3)
Component ID: Y335-3
"Auto 5" Module
Replace only if diagnostic testing proves the module is faulty.
CLAAS Diagnostic Tool
60 05 033 249Required for testing the Auto 5 module.
- Solenoid Valve SV3 (Ratio under torque)0011367040
OEM CLAAS part. Also listed as 1136704. Internal designation Y335-3.
Transmission Solenoid Valve
11367040Explicitly listed for Arion 500/600 series and Axion 800 series tractors (also listed as 1136704)
Transmission Solenoid Valve
0713290Also listed as 071329 and 0000713290. Confirm correct part number with a CLAAS dealer using the tractor's serial number
- Transmission Solenoid Valve0000404430
Listed for a wide range of Claas machines. Confirm correct part number with a CLAAS dealer using the tractor's serial number
- Transmission Solenoid Valve6005019470
Confirm correct part number with a CLAAS dealer using the tractor's serial number