7648h

CLAAS 7648h – Claas Tr2 A57 2 Transmission Module: Low Current Measured on Solenoid Valve SV3 Return

Issue description

The actual current measured on the solenoid valve SV3 return is less than the setpoint value. This may trigger an audio warning and request an ISC reset. The issue may be related to an open or short circuit in the solenoid valve supply harness or a fault with the solenoid valve SV3 itself.

Check the cause

  1. The solenoid valve supply harness for possible open circuit

  2. The solenoid valve for possible short circuit to earth

  3. The solenoid valve SV3 (Y335-3)

Repair steps

  1. Inspect

    Check the solenoid valve supply harness for possible open circuit.

  2. Inspect

    Check the solenoid valve for possible short circuit to earth.

  3. Replace

    If required, replace the solenoid valve SV3 (Y335-3) using the “Auto 5” module and tool n° 60 05 033 249.