Id7649h / 7649h (442)

CLAAS Id7649h / 7649h (442) – TR2 (A57-2) Transmission Control Module: Current sent to solenoid valve SV3 is insufficient (current regulation problem)

Issue description

The control module is not detecting the expected electrical current draw from the SV3 solenoid valve, which typically points to high resistance, low voltage, or a failing solenoid coil. This fault triggers an audio warning and requests an "ISC" reset.

Applies to these machines

  • Axion 810
  • Axion 820
  • Axion 850
  • Arion 610
  • Arion 620
  • Arion 630
  • Arion 640
  • Arion 650
  • Arion 510
  • Arion 530
  • Arion 550
  • Arion 410
  • Arion 430

Check the cause

  1. Check the battery voltage to ensure the system is receiving adequate power

  2. Check for a possible resistance on the solenoid valve supply harness

  3. Check the solenoid valve SV3 itself (CLAAS Component Number Y335-3)

  4. Check the connectors and continuity of the harnesses linking the transmission module to the component

  5. Check for any short-circuits or open circuits in the wiring

  6. Check the component's resistance

  7. Check the sources of energy (fuses, supply, and ground)

Repair steps

  1. Verify Power

    Test the battery voltage and ensure the tractor's electrical system is operating at the correct voltage.

  2. Inspect Wiring

    Trace the wiring harness from the TR2 (A57-2) transmission module to the SV3 solenoid valve. Look for damaged wires, loose connectors, or corrosion that could cause high electrical resistance. Repair or replace damaged wiring.

  3. Test the Solenoid

    Measure the resistance of the SV3 solenoid valve (Y335-3). If the resistance is out of specification or the coil is open/shorted, replace the solenoid valve.

  4. Module Diagnostics

    If the battery, wiring, and solenoid valve are all in good working order, check the "Auto 5" module using CLAAS diagnostic tool n° 60 05 033 249.

  5. Replace Module

    Change the "Auto 5" module if it is determined to be faulty by the diagnostic tool.

Parts you might need

(1)
  • Ratio under torque solenoid valve (SV3) / Gear solenoid valve under SV3 torque

    Y335-3

    Generic/Aftermarket Fitment: Eaton SV3-10-C-0-24DG

Get help to fix this fault by requesting a quote

Browse other CLAAS codes