CLAAS Id764Ah / 764Ah (443) – TR2 (A57-2) Transmission Control Module: Supply voltage measured on solenoid valve SV2 when the driver is not controlled (setpoint PWM = 0).
Issue description
The control module is detecting a 12V supply voltage on the circuit for solenoid valve SV2 even though the module is commanding a 0% duty cycle (meaning the valve should be completely turned off). This indicates a short-to-power in the wiring harness or an internal fault within the control module keeping the circuit energized.
Applies to these machines
9 machines- Arion 410
- Arion 420
- Arion 430
- Arion 510
- Arion 610
- Arion 630
- Arion 640
- Axion 810
- Axion 850
Check the cause
Check for a possible 12 V short circuit on the solenoid valve SV2 (Y335-2) power supply harness
Verify the connectors and the continuity of the harnesses linking the TR2 module to the SV2 solenoid, looking for pinched wires, chafing, or melted insulation
Check the resistance of the SV2 solenoid valve to ensure it is not internally shorted
Test the Auto 5 (TR2) module using CLAAS diagnostic tool n° 60 05 033 249
Repair steps
Power Down
Turn off the tractor and disconnect the battery to prevent accidental shorts during testing.
Locate Components
Locate the TR2 (A57-2) Transmission Control Module and the SV2 (Y335-2) "Ratio under torque" solenoid valve on the transmission valve block.
Isolate the Circuit
Disconnect the wiring harness connector at the SV2 solenoid and at the TR2 module.
Test for Short to Power
Reconnect the battery and turn the key to the ON position (engine off). Use a multimeter to measure voltage on the SV2 supply pin at the harness connector. If 12V is present while the module is disconnected, the wiring harness has a short to power and must be repaired or replaced.
Test the Solenoid
Measure the resistance across the pins of the SV2 solenoid valve. If it falls outside OEM specifications (or is shorted to ground), replace the solenoid valve.
Test/Replace the Module
If the wiring harness is completely intact (no short to 12V) and the solenoid tests fine, the fault lies within the TR2 (Auto 5) module itself (internal driver shorted closed). Use CLAAS tool n° 60 05 033 249 to verify module failure. Replace the TR2 module if required.
Clear Codes
Reconnect all components, clear the fault codes via the diagnostic interface, and test drive the tractor to ensure the transmission shifts correctly and the code does not return.
Parts you might need
(3)Solenoid Valve SV2 (Y335-2)
Ratio under torque solenoid valve / Gear under torque solenoid valve
Transmission Control Module TR2 (A57-2) / "Auto 5" Module
Diagnostic Tool
60 05 033 249Required for module testing and calibration