764Ch

CLAAS 764Ch: TR2 (A57-2) - Current Consumed by Solenoid Valve SV2 Exceeds 1,4 A

Issue description

The current consumed by solenoid valve SV2 exceeds the maximum allowable value of 1,4 A. This condition triggers an audio warning and requests an ISC reset.

Check the cause

  1. Solenoid valve SV2 for signs of damage or malfunction

  2. Wiring and connections to solenoid valve SV2 for continuity and integrity

  3. Power supply to solenoid valve SV2 for proper voltage and current levels

Repair steps

  1. Inspect solenoid valve SV2

    Check for physical damage, wear, or internal faults that may cause excessive current draw.

  2. Test wiring and connections

    Verify that all wiring and connections to solenoid valve SV2 are secure and free from corrosion or damage.

  3. Measure power supply

    Use a multimeter to check the voltage and current supplied to solenoid valve SV2 to ensure it meets specifications.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes