CLAAS 764Dh – Claas Tr2 A57 2 Transmission Module: Low Current Measured on Solenoid Valve SV2 Return
Issue description
The actual current measured on the solenoid valve SV2 return is less than the setpoint value. This may trigger an audio warning and request an ISC reset. The issue may be related to the solenoid valve supply harness or the solenoid valve itself.
Check the cause
For a possible open circuit in the solenoid valve supply harness
For a possible short circuit to earth on the solenoid valve
The solenoid valve SV2 (Y335-2)
Repair steps
Check the solenoid valve supply harness
Inspect for any open circuits in the solenoid valve supply harness.
Check for short circuits to earth
Inspect the solenoid valve for a possible short circuit to earth.
Test the solenoid valve SV2
Use the “Auto 5” module with tool n° 60 05 033 249 to test the solenoid valve SV2.
Replace the solenoid valve if required
If the solenoid valve SV2 is found to be faulty, replace it as needed.