CLAAS Id764Eh / 764Eh (447) – TR2 (A57-2) / Auto 5: Insufficient current sent to solenoid valve SV2
Issue description
The transmission control module is detecting that the electrical current reaching the SV2 solenoid valve is lower than the required setpoint, triggering an audio warning and requesting an 'ISC' reset.
Applies to these machines
18 machines- Arion 410
- Arion 420
- Arion 430
- Arion 510
- Arion 520
- Arion 530
- Arion 540
- Arion 550
- Arion 610
- Arion 620
- Arion 630
- Arion 640
- Arion 650
- Axion 810
- Axion 820
- Axion 830
- Axion 840
- Axion 850
Check the cause
Check the tractor's battery voltage to ensure it is sufficient and stable
Inspect the wiring harness supplying power to the SV2 solenoid valve for possible high resistance, open circuits, or damaged connectors
Test the SV2 solenoid valve (Component designation: Y335-2) for proper resistance and operation
Test the 'Auto 5' / TR2 module using CLAAS diagnostic tool n° 60 05 033 249 if the wiring and valve are intact
Repair steps
Turn off the tractor and ensure the master switch is off before disconnecting any transmission components.
Ensure the master switch is off before disconnecting any transmission components.
Locate the SV2 solenoid valve (Y335-2).
This is the 'Ratio under torque solenoid valve' or 'Gear solenoid valve under torque' on the Hexashift transmission block.
Disconnect the harness to the SV2 valve and use a multimeter to check the continuity of the harness back to the TR2 (A57-2) module.
Clean the contacts to eliminate any resistance.
Measure the internal resistance of the SV2 solenoid valve.
If it is out of specification (causing the current draw to be insufficient), the valve must be replaced.
If the valve and wiring test fine, connect the CLAAS diagnostic tool (part n° 60 05 033 249) to test the 'Auto 5' module.
Replace the module if it is failing to regulate current properly.
Once the repair is complete, clear the fault codes and perform an 'ISC' reset.
This is requested by the system when this code is triggered.
Parts you might need
(3)Solenoid Valve SV2 (Component Y335-2)
0011367040Ratio under torque solenoid valve / Gear solenoid valve under torque. Fits Hexashift transmission blocks on Arion 500/600 and Axion 800 series. Alternative part number: 1136704.
Transmission Control Module TR2 (A57-2) / Auto 5 Module
Part number varies heavily by specific tractor serial number and configuration; requires dealer programming.
CLAAS Diagnostic Tool
60 05 033 249Used for testing the Auto 5 module.
Get help to fix this fault by requesting a quote