764Fh

CLAAS 764Fh – Claas Tr2 A57 2 Transmission Module: Supply Voltage Measured on Solenoid Valve SV1 When Not Controlled

Issue description

A supply voltage is detected on solenoid valve SV1 when the driver is not controlled, indicated by a setpoint PWM of 0. This may trigger an audio warning and request an ISC reset. The issue may be caused by a 12 V short circuit on the solenoid valve power supply harness.

Check the cause

  1. Solenoid valve power supply harness for a possible 12 V short circuit

  2. The “Auto 5” module for potential issues

Repair steps

  1. Inspect

    Inspect the solenoid valve power supply harness for a possible 12 V short circuit.

  2. Test

    Use tool n° 60 05 033 249 to test the “Auto 5” module.

  3. Replace

    If the “Auto 5” module is found to be faulty, replace it as required.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes