CLAAS 765Eh – Claas Tr2 A57 2 Transmission Module: Power Management Function Faulty Due to Loss of Engine Speed Information
Issue description
The Power Management function is faulty because the system has lost engine speed information on the Powertrain CAN bus. As a result, the lowest power curve is selected by default. This issue requires checking the engine module and the Powertrain CAN bus network.
Check the cause
The engine module (A15)
The Powertrain CAN bus network
The “Auto 5” module using tool n° 60 05 033 249
Repair steps
Check the engine module (A15)
Verify the functionality and connection of the engine module (A15) to ensure it is transmitting correct engine speed information.
Inspect the Powertrain CAN bus network
Examine the Powertrain CAN bus network for any faults, disconnections, or interference that may be causing the loss of engine speed information.
Use tool n° 60 05 033 249 to check the “Auto 5” module
Use the specified tool to access and verify the status of the “Auto 5” module, and make any necessary adjustments as required.
Parts you might need
(0)Get help to fix this fault by requesting a quote