7682h
CLAAS 7682h – Claas Tr3 A57 3 Transmission Module: Short-circuit to 12V of the rear PTO solenoid valve
Issue description
A short-circuit to 12V has been detected in the rear PTO solenoid valve. This issue is associated with the PTO being off. The cause is likely a fault in the power supply harness of the solenoid valve.
Check the cause
The solenoid valve power supply harness for a possible 12V short circuit
The condition of the rear PTO solenoid valve
Repair steps
Inspect
Inspect the solenoid valve power supply harness for signs of damage, wear, or a 12V short circuit.
Test
Use the “Auto 5” module with tool number 60 05 033 249 to test the solenoid valve and identify any faults.
Replace
If a fault is identified, replace the affected component as required.
Parts you might need
(0)Get help to fix this fault by requesting a quote