7686h

CLAAS 7686h – Claas Tr3 A57 3 Transmission Module: Battery Fault Out of Range (10 Volts – 16 Volts)

Issue description

The battery voltage is outside the acceptable range of 10 volts to 16 volts. This issue is linked to the PTO being off. The fault may be caused by an issue with the battery or the 'Auto 5' module.

Check the cause

  1. The battery

  2. The 'Auto 5' module

Repair steps

  1. Check

    The battery for proper voltage and condition.

  2. Check

    The 'Auto 5' module using tool n° 60 05 033 249.

  3. Replace

    The 'Auto 5' module if it is found to be faulty.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote