7691h

CLAAS 7691h: Fault in the solenoid valve supply harness (Y324)

Issue description

The fault code indicates a potential issue with the solenoid valve supply harness (Y324). This may involve an open circuit or a problem with the solenoid valve winding (Y324). The 'Auto 5' module may need to be checked and replaced if necessary.

Check the cause

  1. The solenoid valve supply harness (Y324)

  2. The resistance of the solenoid valve winding (Y324)

  3. The 'Auto 5' module

Repair steps

  1. Check for an open circuit in the solenoid valve supply harness (Y324)

    Inspect the wiring and connections related to the solenoid valve supply harness (Y324) for any breaks or poor connections.

  2. Measure the resistance of the solenoid valve winding (Y324)

    Use a multimeter to measure the resistance of the solenoid valve winding (Y324) and compare it to the expected value.

  3. Use tool n° 60 05 033 249 to check the 'Auto 5' module

    Use the specified tool to test the 'Auto 5' module and replace it if required.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes