7692h

CLAAS 7692h – Claas Tr3 A57 3 Transmission Module: Short-circuit to ground of the automatic hand brake disengaging solenoid valve

Issue description

A short-circuit to ground has been detected in the automatic hand brake disengaging solenoid valve. This fault prevents the automatic hand brake from disengaging properly. A release screw can be used to manually disengage the automatic hand brake.

Check the cause

  1. The solenoid valve supply harness (Y324) for a possible open circuit

  2. The solenoid valve (Y324) for a possible short circuit to earth

Repair steps

  1. Use the release screw

    Manually disengage the automatic hand brake using the release screw.

  2. Inspect the solenoid valve supply harness (Y324)

    Check for a possible open circuit in the solenoid valve supply harness (Y324).

  3. Inspect the solenoid valve (Y324)

    Check for a possible short circuit to earth on the solenoid valve (Y324).

  4. Use the specified tool

    Use the “Auto 5” module with tool n° 60 05 033 249 to diagnose and, if required, replace the solenoid valve (Y324).