CLAAS 7692h – Claas Tr3 A57 3 Transmission Module: Short-circuit to ground of the automatic hand brake disengaging solenoid valve
Issue description
A short-circuit to ground has been detected in the automatic hand brake disengaging solenoid valve. This fault prevents the automatic hand brake from disengaging properly. A release screw can be used to manually disengage the automatic hand brake.
Check the cause
The solenoid valve supply harness (Y324) for a possible open circuit
The solenoid valve (Y324) for a possible short circuit to earth
Repair steps
Use the release screw
Manually disengage the automatic hand brake using the release screw.
Inspect the solenoid valve supply harness (Y324)
Check for a possible open circuit in the solenoid valve supply harness (Y324).
Inspect the solenoid valve (Y324)
Check for a possible short circuit to earth on the solenoid valve (Y324).
Use the specified tool
Use the “Auto 5” module with tool n° 60 05 033 249 to diagnose and, if required, replace the solenoid valve (Y324).