Id76A7h / 76A7h (718)

CLAAS Id76A7h / 76A7h (718) – REH (A58) Rear Lifting Module: Missing engine running information on Powertrain CAN bus and missing alternator D+ load signal

Issue description

The REH (A58) lifting module does not receive any engine running information on the Powertrain CAN bus (or this information is in error on the Powertrain CAN bus), and the alternator’s D+ load signal is missing. The rear lifting function becomes inactive/locked.

Applies to these machines

  • Axion 800
  • Axion 810
  • Axion 820
  • Axion 830
  • Axion 840
  • Axion 850
  • Axion 920
  • Axion 950
  • Arion 410
  • Arion 430
  • Arion 510
  • Arion 610
  • Arion 630
  • Arion 640

Check the cause

  1. The Powertrain CAN bus network: Check for communication errors, shorts, or open circuits.

  2. The Alternator D+ Signal: Verify the physical D+ (charge/engine running) signal wire from the alternator.

  3. The TR2 transmission module (A57-2): Ensure it is communicating properly on the CAN bus.

  4. The engine module ENG (A15): Verify it is broadcasting engine running data.

  5. The lifting module REH (A58): Check its power, ground, and CAN connections.

Repair steps

  1. Verify the Alternator D+ Circuit

    Check the D+ terminal for output when the engine is running. Inspect the wiring harness from the alternator to the main cab harness for breaks, corrosion, or loose connectors.

  2. Inspect Harnesses and Connectors

    Check the connectors and continuity of the harnesses linking the REH (A58), ENG (A15), and TR2 (A57-2) modules. Look for pushed pins, moisture intrusion, or chafed wires.

  3. Test Power and Ground

    Check the sources of energy for the REH (A58) module. Verify all related fuses, main power supply relays, and ground straps are secure and providing proper voltage.

  4. Test CAN Bus Integrity

    Measure the resistance of the Powertrain CAN bus (should be approximately 60 ohms with batteries disconnected). Check for short-circuits to ground or power on the CAN-High and CAN-Low lines.

  5. Software/Calibration Check

    If the wiring is fully intact, check the compatibility of the program versions, settings, and calibration of the ENG, TR2, and REH modules using the CLAAS Diagnostic System (CDS).

  6. Component Replacement

    If a module is found to be internally shorted or failing to broadcast/receive on the CAN bus despite good power, ground, and wiring, replace the faulty component (Alternator or REH A58 module).

Parts you might need

(4)
  • REH (A58) Rear Lifting Module

    Generic OEM designation: "Auto 5" type module. Requires programming via CLAAS CDS upon replacement.

  • Alternator

    Generic part; ensure the replacement unit features a D+ terminal for the load signal.

  • ENG (A15) Engine Control Module

    OEM designation: HPCR 14 type electronic unit.

  • TR2 (A57-2) Transmission Module

    OEM designation: "Auto 5" type module.