76A7h

CLAAS 76A7h: REH (A58) Lifting Module Does Not Receive Engine Running Information

Issue description

The REH (A58) lifting module is not receiving engine running information on the Powertrain CAN bus, or the information received is incorrect. Additionally, the alternator's D+ load signal is missing, resulting in the lifting function being inactive.

Check the cause

  1. Powertrain CAN bus communication with the REH (A58) lifting module

  2. Alternator's D+ load signal connection and functionality

  3. Powertrain CAN bus wiring and connectors

  4. REH (A58) lifting module power supply and grounding

Repair steps

  1. Verify Powertrain CAN bus communication

    Check the communication between the REH (A58) lifting module and the Powertrain CAN bus using diagnostic tools.

  2. Inspect alternator's D+ load signal

    Check the alternator's D+ load signal for continuity and proper connection to the REH (A58) lifting module.

  3. Check Powertrain CAN bus wiring

    Inspect the wiring and connectors of the Powertrain CAN bus for damage, corrosion, or loose connections.

  4. Test REH (A58) lifting module power supply

    Ensure the REH (A58) lifting module is receiving proper power and grounding.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes