76B7h
CLAAS 76B7h – Claas Reh A58 Lifting Module: Voltage of the down speed instruction non valid
Issue description
The voltage of the down speed instruction is not valid, which indicates that the control of the down speed is inactive. The lowest down speed is selected by default.
Check the cause
The lifting control panel (V22)
The lifting module REH (A58)
Repair steps
Inspect
Inspect the lifting control panel (V22) for any visible damage or malfunction.
Test
Test the lifting module REH (A58) to confirm its functionality.
Verify
Verify the connection and operation of the lifting control panel (V22) with the lifting module REH (A58).
Parts you might need
(0)Get help to fix this fault by requesting a quote