76B7h

CLAAS 76B7h – Claas Reh A58 Lifting Module: Voltage of the down speed instruction non valid

Issue description

The voltage of the down speed instruction is not valid, which indicates that the control of the down speed is inactive. The lowest down speed is selected by default.

Check the cause

  1. The lifting control panel (V22)

  2. The lifting module REH (A58)

Repair steps

  1. Inspect

    Inspect the lifting control panel (V22) for any visible damage or malfunction.

  2. Test

    Test the lifting module REH (A58) to confirm its functionality.

  3. Verify

    Verify the connection and operation of the lifting control panel (V22) with the lifting module REH (A58).