76BCh

CLAAS 76BCh: Lifting Module Does Not Receive Lifting Up Mode Selection Information

Issue description

The REH (A58) lifting module is not receiving the lifting up mode selection information, or the information received is incorrect on the Powertrain CAN bus. As a result, the lifting up mode is inactive.

Check the cause

  1. Powertrain CAN bus communication

  2. REH (A58) lifting module

  3. Lifting up mode selection input

Repair steps

  1. Check the Powertrain CAN bus for communication errors

    Use diagnostic tools to verify the integrity of the Powertrain CAN bus and ensure there are no communication failures.

  2. Inspect the REH (A58) lifting module

    Verify that the REH (A58) lifting module is properly connected and functioning as expected.

  3. Verify the lifting up mode selection input

    Ensure that the input source for the lifting up mode selection is providing correct and valid information.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes