76BCh

CLAAS 76BCh – REH: Powertrain CAN Bus or Speed Sensor Fault

Issue description

The REH (A58) lifting module is not receiving the 'lifting up mode selection information', or the data received from the Powertrain CAN bus is invalid. This communication error prevents the lifting mode from activating as a safety measure to prevent uncontrolled rear hitch movement.

Applies to these machines

  • Arion 640-510
  • Axion 850-810

Check the cause

  1. Perform a visual inspection for obvious damage to wiring harnesses around the rear hitch, under the cab, and near the radar sensor

  2. Check for moisture intrusion into CAN bus connectors, especially if the tractor has been pressure washed or operated in wet conditions

  3. Analyze all active fault codes using the CLAAS Diagnostic System (CDS) if available, as a communication fault on a primary module can cause secondary codes in the REH

Repair steps

  1. Perform basic CAN bus health check

    Turn ignition OFF. Measure resistance between Powertrain CAN_H and CAN_L wires. A healthy network reads approximately 60 Ohms. A reading of ~120 Ohms indicates a missing terminating resistor or open circuit. Less than 60 Ohms suggests a short circuit or faulty module.

  2. Check for CAN bus shorts

    With ignition OFF, measure resistance from CAN_H to ground and CAN_L to ground (should be mega-ohms). Turn ignition ON (engine off) and measure DC voltage to ground to ensure no significant voltage when the bus is asleep.

  3. Isolate faulty component

    If resistance is incorrect, disconnect modules one by one from the Powertrain CAN bus, starting with the forward speed sensor (B230). Re-measure bus resistance after each disconnection. If resistance normalizes, the disconnected module is likely faulty. If not, inspect the wiring harness for chafing or damage.

  4. Inspect forward speed sensor (B230)

    Locate the radar sensor at the front of the tractor. Check the sensor and connector for physical damage, corrosion, or loose connections. Substitute with a known good sensor if the CAN wiring tests good.

  5. Inspect and replace REH (A58) module

    Check connectors and wiring at the REH module. If all CAN networks test correctly and other causes are eliminated, the REH module may have an internal fault. Replacement requires configuration with the CLAAS Diagnostic System (CDS).

Parts you might need

(2)
  • Component B230. Alternate part numbers may include 0000118100, 0000118153, or 0000117602 depending on exact model. Verify with dealer.

  • Lifting Module

    Component REH (A58). Must be sourced through an official CLAAS dealer and configured using CDS.

Get help to fix this fault by requesting a quote