76BEh

CLAAS 76BEh – CEBIS: Right Load Sensor Overload and Ignored

Issue description

The right-side load sensor, a core component of the QUANTIMETER yield monitoring system located at the top of the clean grain elevator, is registering a force that exceeds its design capacity. The CEBIS control unit has determined the reading to be invalid and is ignoring the sensor's input for yield calculations. This overload condition can be caused by a sudden mechanical impact, a short circuit providing excessive voltage, or an internal failure of the sensor's strain gauge, which will affect the proper functioning of the yield monitoring system.

Applies to these machines

  • LEXION
  • TRION
  • TUCANO

Check the cause

  1. Inspect the top of the clean grain elevator for any obstructions, debris, or signs of mechanical binding that could interfere with the load sensor's impact plate.

  2. Examine the sensor itself for any visible damage, such as cracks, corrosion, or deformation from being struck.

  3. Inspect the associated wiring harness for damage, looking for chafed, pinched, or melted wires, and check connectors for corrosion or pushed-back pins.

  4. Using a multimeter, check for a short circuit to ground by disconnecting the sensor and measuring resistance between each wire in the harness and the machine's chassis ground (there should be no continuity).

  5. Check the sensor's internal resistance by measuring across its signal and excitation leads with the sensor disconnected to check for internal damage.

  6. Verify the sensor's voltage supply at the connector to ensure it is stable and within the specified range.

  7. Review the yield monitor's calibration status in the CEBIS terminal to ensure it is not outdated or improperly performed.

  8. Perform a 'zero throughput' calibration with the processor and feeder house engaged but with no crop in the machine.

  9. If the issue persists, consider performing a full multi-point calibration, harvesting loads at different speeds to ensure accuracy across a range of flow rates.

Repair steps

  1. Isolate the fault

    Based on the diagnostic checks, determine if the fault lies with the sensor, wiring, or calibration.

  2. Address wiring issues

    If any wiring faults are found, repair the damaged section of the harness or replace the harness if damage is extensive. Ensure all connections are clean and secure.

  3. Recalibrate

    If no physical or electrical faults are found, perform a full and accurate calibration of the QUANTIMETER system as per the machine's operator's manual.

  4. Replace the sensor

    If diagnostics confirm the sensor itself has failed (e.g., incorrect internal resistance, no signal, or physical damage), disconnect the electrical connector, unbolt the failed sensor from its mounting at the top of the clean grain elevator, install the new sensor ensuring it is correctly seated and torqued, and reconnect.

  5. Perform post-replacement calibration

    After replacing the sensor, a full calibration of the yield monitoring system is mandatory for accurate readings.

Parts you might need

(4)
  • Alternate part number 0468112002. Claas Lexion Combine Yield Monitor Sensor.

  • Sensor Lens

    0011616

    Alternate part number 00116160. Lens for QUANTIMETER optical sensors on LEXION combines.

  • Generic Sensor

    0505261

    Application unconfirmed, verify with dealer.

  • Generic Sensor

    0155350

    Application unconfirmed, verify with dealer.

Get help to fix this fault by requesting a quote