Issue description
A short-circuit has been detected on the On/Off supply solenoid valve 1. This has caused the suspension to be locked in its current position, preventing normal operation.
Check the cause
Supply solenoid valve 1 (Y321)
On/Off supply circuit for solenoid valve 1
Repair steps
Inspect
Inspect the supply solenoid valve 1 (Y321) for visible damage or short-circuiting.
Test
Test the electrical continuity and insulation of the supply solenoid valve 1 (Y321) using a multimeter.
Replace
If a short-circuit is confirmed, replace the supply solenoid valve 1 (Y321) with a new one.