76DEh

CLAAS 76DEh: Open circuit on the down On/Off solenoid valve 2

Issue description

An open circuit has been detected on the down On/Off solenoid valve 2. As a result, the non-functional suspension is locked in its current position.

Check the cause

  1. The wiring and connections to the down On/Off solenoid valve 2

  2. The integrity of the circuit leading to the down On/Off solenoid valve 2

  3. The functionality of the component identified by this code

Repair steps

  1. Inspect

    Inspect the wiring and connections to the down On/Off solenoid valve 2 for any signs of damage or disconnection.

  2. Test

    Test the circuit leading to the down On/Off solenoid valve 2 to identify any breaks or faults.

  3. Replace

    If a fault is found, replace the affected circuit or the component identified by this code as necessary.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes