76DEh
CLAAS 76DEh: Open circuit on the down On/Off solenoid valve 2
Issue description
An open circuit has been detected on the down On/Off solenoid valve 2. As a result, the non-functional suspension is locked in its current position.
Check the cause
The wiring and connections to the down On/Off solenoid valve 2
The integrity of the circuit leading to the down On/Off solenoid valve 2
The functionality of the component identified by this code
Repair steps
Inspect
Inspect the wiring and connections to the down On/Off solenoid valve 2 for any signs of damage or disconnection.
Test
Test the circuit leading to the down On/Off solenoid valve 2 to identify any breaks or faults.
Replace
If a fault is found, replace the affected circuit or the component identified by this code as necessary.
Parts you might need
(0)Get help to fix this fault by requesting a quote