76EDh
CLAAS 76EDh – Claas Sfa A102 Suspended Axle Module: Supply Voltage Too Low in Suspended Axle Module
Issue description
The supply voltage is below the minimum required level of 10.5 V, which has caused the suspension to become locked in its current position. This issue is related to the voltage source and the suspended axle module.
Check the cause
The voltage source (G001)
The SFA (A102) suspended axle module
Repair steps
Verify the voltage source (G001)
Check the voltage output of the voltage source to ensure it meets the required level.
Inspect the SFA (A102) suspended axle module
Examine the suspended axle module for any signs of malfunction or damage.
Parts you might need
(0)Get help to fix this fault by requesting a quote