Id76F6h / 76F6h

CLAAS Id76F6h / 76F6h – BDG (A103): No message was transmitted by the MFT module although the configuration indicates its presence

Issue description

Communication failure on the tractor's CAN bus network indicating the Cebis terminal module (MFT A30) is failing to transmit. As a result, the Cebis terminal module and its associated functions become inactive or operate in a degraded mode.

Applies to these machines

  • Axion 800 series
  • Axion 810
  • Axion 850
  • Arion 500 series
  • Arion 600 series
  • Arion 510
  • Arion 640
  • Lexion
  • Jaguar
  • Xerion

Check the cause

  1. Check the CLAAS vehicle CAN bus network: Look for physical damage to the network lines.

  2. Check the Cebis terminal module MFT (A30): Ensure the screen is powering on and not physically damaged.

  3. Check the CAN network communication module BDG (A103).

  4. Wiring & Harnesses: Check the connectors and continuity of harnesses linking the BDG and MFT components.

  5. Circuit Testing: Check for any short-circuits or open circuits in the CAN lines.

  6. Power & Ground: Check the sources of energy to the Cebis terminal (fuses, supply voltage, and ground connections).

  7. Software: Check compatibility of program versions, settings, and calibration.

Repair steps

  1. Inspect Power and Ground

    Begin by testing the power supply and ground pins at the Cebis terminal (MFT A30) connector. If the terminal is not receiving power, it cannot broadcast messages on the CAN bus. Replace blown fuses or repair broken power/ground wires as necessary.

  2. Test CAN Bus Continuity

    If power and ground are present, use a multimeter to test the CAN High and CAN Low lines between the Cebis terminal (MFT A30) and the CAN network communication module (BDG A103). Repair any open circuits, or shorts to ground/power.

  3. Inspect Connectors

    Disconnect the harnesses at both the MFT and BDG modules. Inspect the pins for corrosion, pushed-back pins, or moisture ingress. Clean and reseat the connectors.

  4. Component Repair/Replacement

    If the wiring harness, power, and ground are all verified to be in good working order, the fault lies internally within either the Cebis terminal (MFT A30) or the BDG (A103) module. The Cebis terminal is highly susceptible to internal inverter, display, or microcontroller failures. You can either replace the terminal with a new OEM unit or send it to a specialized agricultural electronics repair center.

  5. Calibration

    If a module is replaced, verify software compatibility and perform any necessary calibration via the CLAAS diagnostic tool.

Parts you might need

(21)
  • Cebis Terminal Module (MFT - A30)

    013321.0

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    013321.2

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    013321.3

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    013321.4

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    013322.2

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    013322.3

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    013415.2

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    013740.1

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    013740.2

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    013740.3

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    014600.0

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    014600.1

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    014900.1

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    351052.1

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    0500628.0

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    0021846068

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    2717154.0

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    2717154.1

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • Cebis Terminal Module (MFT - A30)

    2717154.2

    Fits various Axion (810-960), Arion (510-650), Lexion, Jaguar, and Xerion models.

  • CAN Network Communication Module (BDG - A103)

    Specific OEM part number not published in the available search data; refer to the CLAAS Parts Doc catalog using the machine's VIN.

  • Wiring Harness / Connectors

    Generic replacement as needed based on physical inspection.

Get help to fix this fault by requesting a quote

Browse other CLAAS codes