Skip to main content
770Ah

CLAAS 770Ah – BDG (A103): Function 1 and 2 Button Message Missing

Issue description

The system has detected a communication failure between the Function 1 and 2 buttons (typically located on the CMOTION control lever) and the designated control module. The expected signal or message from these buttons is missing, rendering the assigned operations unavailable. This indicates an interruption in the electrical circuit or the CAN bus communication network. The system is designed to return to normal operation automatically once the message from the buttons is successfully received again.

Applies to these machines

  • Axion 810
  • Axion 820
  • Axion 830
  • Axion 840
  • Axion 850
  • Arion 640-510
  • Lexion

Check the cause

  1. Review the fault memory for any other active CAN bus or communication error codes to rule out a wider network problem

  2. Inspect CAN bus connectors, particularly those located under the cab floor, for signs of moisture ingress, corrosion, or damage

  3. Inspect the wiring harness connecting the CMOTION joystick to the main tractor harness for chafing, pinching, or breaks

  4. Verify that the control module (BDG A103) and the joystick have a stable power supply and a clean ground connection

  5. Use a diagnostic tool to monitor the live status of the Function 1 and 2 buttons to see if the control module recognizes the button press, even intermittently

Repair steps

  1. Access components

    Gain access to the underside of the CMOTION joystick and the relevant electrical connectors.

  2. Clean and secure connectors

    Disconnect the electrical connectors for the joystick and any intermediate CAN bus junctions. Inspect for corrosion or bent pins. Clean the contacts with a suitable electrical cleaner and ensure they are dry before reconnecting securely.

  3. Repair wiring

    If any damage is found in the wiring harness during the diagnostic checks, repair the affected wires. Ensure all repairs are sealed against moisture.

  4. Replace component

    If the wiring and connectors are in good condition, the fault is likely within the button assembly itself or the internal circuitry of the joystick. Replace the component containing the buttons (CMOTION joystick or button assembly).

  5. Clear codes and test

    After completing the repair, clear all related fault codes from the system and verify that the fault does not return. Test the functionality of the Function 1 and 2 buttons to ensure they are operating correctly.

Parts you might need

(3)
  • CMOTION Joystick Button Assembly / CMOTION Joystick

    Specific part number varies by machine model and serial number. Consult the CLAAS Parts Doc system to identify the correct OEM part.

  • Alternative OEM part numbers include 05583752, 0005598340. Verify by serial number.

  • BDG (A103) Control Module

    4990252

    Generic CLAAS module part number found; critical to verify correct part number from a CLAAS parts catalog using serial number.