CLAAS 7725h – ECM: Charge-Air Temperature Sensor Fault

Issue description

The Engine Control Module (ECM) has detected a short circuit to ground (FMI 4) in the charge-air temperature sensor's electrical circuit, indicating an abnormally low voltage or a direct, unintended path to ground from the sensor's signal wire. This sensor measures the temperature of compressed air from the turbocharger before it enters the intake manifold. A fault with this sensor can lead to symptoms such as the cooling fan running constantly at high speed, even with a cold engine, and potential impacts on overall engine performance.

Applies to these machines

  • AXION 810 Stage V

Check the cause

  1. Visually inspect the charge-air temperature sensor (component B049) and its wiring harness for physical damage, corrosion in the connectors, heat damage, or chafing against engine components.

  2. Using a diagnostic tool, compare the sensor's temperature reading to the ambient air temperature after the machine has been off for an extended period to check for plausibility.

  3. Disconnect the sensor and check for a short circuit to ground on the signal wire in the harness.

  4. Measure the resistance of the sensor itself and compare it to the manufacturer's specifications.

  5. With the key on and the sensor disconnected, measure the voltage on the signal wire to ensure the ECM is providing the correct reference voltage.

Repair steps

  1. Confirm the fault

    Using a CLAAS-compatible diagnostic tool, confirm that DTC 7725 with FMI 4 is active or logged in the ECM.

  2. Perform Diagnostics

    Carry out the diagnostic checks listed above to isolate the failure to the sensor, wiring, or connector.

  3. Repair Wiring

    If the wiring harness is found to be damaged, chafed, or shorted, repair the affected section. Ensure all repairs are sealed against moisture to prevent future issues. If a connector is corroded, clean or replace it.

  4. Replace the Sensor

    If the diagnostic checks confirm the sensor itself is faulty, it must be replaced.

  5. Clear Fault Code

    After the repair or replacement is complete, use the diagnostic tool to clear the fault code from the ECM's memory.

  6. Verify Repair

    Start the engine and let it run while monitoring the live data from the charge-air temperature sensor. Ensure the readings are plausible and that the fault code does not reappear.

Parts you might need

(3)
  • Verify exact part number with an authorized CLAAS dealer using the tractor's serial number.

  • Charge-Air Temperature Sensor

    6575680

    Potential alternate part number. Verify by serial number.

  • Charge-Air Temperature Sensor

    714705CK

    Potential alternate part number. Verify by serial number.

Get help to fix this fault by requesting a quote