CLAAS Id7779h / 7779h (2630 03) – ENG (A15): Input voltage of the fresh air intake temperature high
Issue description
The engine control unit detects an abnormally high voltage signal from the fresh air intake temperature sensor (indicating a potential short to power or an open circuit). As a failsafe, the engine calculator defaults to an assumed intake fresh air temperature of 50°C, and the engine protection function related to the fresh air maximum temperature for the EGR (Exhaust Gas Recirculation) system is deactivated.
Applies to these machines
15 machines- Axion 810
- Axion 840
- Axion 850
- Axion 960
- Arion 410
- Arion 430
- Arion 510
- Arion 530
- Arion 550
- Arion 620
- Arion 640
- Arion 650
- Jaguar
- Lexion
- Tucano
Check the cause
Inspect the B222 fresh air intake temperature sensor for physical damage.
Check the wiring harness and connectors between the B222 sensor and the ENG (A15) module for short-circuits to 12V, open circuits, or severe corrosion.
Test the sensor's internal resistance using a multimeter to check for internal failure.
Check the power and ground sources (fuses, power supply, and ground connections) to the sensor circuit.
Verify the integrity of the ENG (A15) engine module if the sensor and wiring test perfectly.
Repair steps
Turn off the engine, remove the key, and disconnect the battery to prevent electrical shorts during repair.
Locate the B222 Fresh Air Intake Temperature Sensor on the engine's intake air circuit.
Often located near or just after the charge air cooler/intercooler.
Disconnect the electrical pigtail from the B222 sensor. Inspect the pins on both the sensor and the harness for damage, moisture, or corrosion.
Clean with contact cleaner if necessary.
Using a multimeter, test the wiring continuity from the sensor connector back to the ENG (A15) module pins.
Repair any broken, chafed, or shorted wires.
Unthread/remove the B222 sensor from the intake piping.
Do this if the wiring is intact but the sensor fails resistance testing (or if the fault persists after wiring repair).
Install the new fresh air intake temperature sensor and tighten it to the manufacturer's torque specifications.
Reconnect the electrical harness.
Reconnect the battery, start the engine, and use the CLAAS Diagnostic System (CDS) or a compatible scan tool to clear the fault code.
Verify that the sensor is now reading the correct ambient/intake temperature rather than the 50°C default.
Parts you might need
(1)Fresh Air Intake Temperature Sensor (Component B222)
6575680Always verify the exact part number with a CLAAS dealer using your machine's specific serial number and engine type.