77BBh

CLAAS 77BBh – Claas Hyd A60 Claas Hydraulic Module: Electrodistributor 2 Faulty in Module A105-2

Issue description

The electrodistributor 2 remains in neutral during initialization, indicating a fault in the EEPROM on valve 2. This issue is associated with the electrodistributor module (A105-2).

Check the cause

  1. Electrodistributor 2

  2. EE PROM on valve 2

  3. Electrodistributor module (A105-2)

Repair steps

  1. Inspect

    Check the electrodistributor 2 for visible damage or connection issues.

  2. Test

    Verify the functionality of the electrodistributor module (A105-2) using the appropriate diagnostic tool.

  3. Replace

    If the fault persists, replace the electrodistributor 2 or the affected component identified by this code.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes