CLAAS Id77C7h / 77C7h (43) – HYD (A60): Internal position sensor of hydraulic valve 2 faulty
Issue description
The internal position sensor of hydraulic valve 2 is faulty, with the system detecting a probable open circuit. As a direct safety response to this condition, the system forces electrodistributor 2 to automatically return to its neutral position.
Applies to these machines
6 machines- Axion 800 series
- Axion 810
- Axion 820
- Axion 830
- Axion 840
- Axion 850
Check the cause
Note all error codes present on the tractor to analyze interactions, as one error code can generate another
Check the connectors and the continuity of the wiring harnesses linking the HYD (A60) module to the electrodistributor module (A105-2)
Inspect the wiring for any short-circuits or open circuits
Check the internal resistance of the valve 2 position sensor
Verify the sources of energy to the module, including fuses, power supply, and ground connections
Check the component's physical operating conditions to rule out mechanical seizing, extreme temperatures, or abnormal hydraulic pressure
Repair steps
Identify the error code at the origin of the anomaly (in this case, valve 2 position sensor open circuit).
Locate the electrodistributor module (A105-2) on the tractor's hydraulic valve block.
Disconnect the harness and perform the electrical continuity and resistance measurements required to isolate whether the open circuit is in the tractor's wiring harness or internal to the valve's sensor.
If the wiring harness, power, and ground are intact, the internal position sensor of the electrodistributor is confirmed faulty.
Replace the faulty electrodistributor module / spool valve assembly.
Clear all error codes from the system.
Test the tractor's hydraulic functions and operate valve 2 to ensure the anomaly does not appear again.
Parts you might need
(1)Electrodistributor module / Electronic Spool Valve Assembly / Hydraulic Lift Valve
6005028082Fits CLAAS Axion and Ares series tractors (e.g., Ares 836, 715, and Axion 800 series). The electro-hydraulic valves on these machines are often manufactured by Danfoss.
Get help to fix this fault by requesting a quote