CLAAS 77D5h – Claas Hyd A60 Claas Hydraulic Module: Valve 3 Drawer Exceeded the Instruction - Electrodistributor 3 Returns to Neutral
Issue description
The valve 3 drawer has exceeded the instruction, which is caused by the electrodistributor 3 returning to neutral. This indicates an issue with the electrodistributor 3 that needs to be checked and resolved.
Check the cause
The electrodistributor 3
The electrodistributor module (A105-3)
Repair steps
Inspect
Inspect the electrodistributor 3 for signs of damage or malfunction.
Test
Test the electrodistributor 3 to confirm if it is returning to neutral as described.
Replace
If the electrodistributor 3 is faulty, replace it with a compatible unit.
Parts you might need