77DAh
CLAAS 77DAh – Claas Hyd A60 Claas Hydraulic Module: Power Supply of Valve 3 Too High (> 42 V) - Electrodistributor 3 Returns to Neutral
Issue description
The power supply of valve 3 is exceeding 42 V, which may be caused by electrodistributor 3 returning to neutral. This condition requires inspection of the electrodistributor module (A105-3) to identify the root cause.
Check the cause
The electrodistributor 3 for neutral position return
The power supply voltage to valve 3
The electrodistributor module (A105-3) for proper operation
Repair steps
Inspect
Check the electrodistributor 3 for signs of malfunction or improper return to neutral.
Measure
Measure the power supply voltage to valve 3 to confirm it exceeds 42 V.
Test
Test the electrodistributor module (A105-3) for correct functionality according to the service manual.
Parts you might need
(0)Get help to fix this fault by requesting a quote