77DAh

CLAAS 77DAh – Claas Hyd A60 Claas Hydraulic Module: Power Supply of Valve 3 Too High (> 42 V) - Electrodistributor 3 Returns to Neutral

Issue description

The power supply of valve 3 is exceeding 42 V, which may be caused by electrodistributor 3 returning to neutral. This condition requires inspection of the electrodistributor module (A105-3) to identify the root cause.

Check the cause

  1. The electrodistributor 3 for neutral position return

  2. The power supply voltage to valve 3

  3. The electrodistributor module (A105-3) for proper operation

Repair steps

  1. Inspect

    Check the electrodistributor 3 for signs of malfunction or improper return to neutral.

  2. Measure

    Measure the power supply voltage to valve 3 to confirm it exceeds 42 V.

  3. Test

    Test the electrodistributor module (A105-3) for correct functionality according to the service manual.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other CLAAS codes