Id77E0h / 77E0h (11)

CLAAS Id77E0h / 77E0h (11) – HYD (A60): "Instruction" message of valve 4 is not received or is improbable

Issue description

The "Instruction" message of valve 4 is not received or is improbable. As a safety measure, electrodistributor 4 (Valve 4) is forced to return to the neutral position.

Applies to these machines

  • Axion 800 series
  • Axion 810
  • Axion 820
  • Axion 830
  • Axion 840
  • Axion 850

Check the cause

  1. Check the communication lines for the hydraulic CAN bus network

  2. Check the connectors and continuity of the harnesses linking the HYD (A60) module to the electrodistributor module (A105-4)

  3. Test for any short-circuits or open circuits in the wiring

  4. Check the sources of energy, including fuses, power supply voltage, and ground connections to the valve

  5. Check the electrodistributor's operating conditions (e.g., mechanical seizing, pressure, temperature)

Repair steps

  1. Document Codes

    Note all error codes present on the tractor, as CAN bus errors can sometimes cascade and generate secondary codes.

  2. Inspect Connections

    Locate the electrodistributor module (A105-4) for Valve 4. Disconnect the harness and inspect the pins for corrosion, moisture, or pushed-out terminals. Reconnect securely.

  3. Test the CAN Bus

    Using a multimeter or oscilloscope, verify the integrity of the Hydraulic CAN bus network between the HYD (A60) module and the A105-4 valve module.

  4. Verify Power/Ground

    Ensure the valve is receiving proper operating voltage and has a clean ground.

  5. Replace/Swap Component

    If the wiring, power, and CAN signals are intact but the "Instruction" message is still not being received, the electrodistributor module (A105-4) itself has likely failed internally and must be replaced.

  6. Clear and Retest

    Clear all error codes from the system, restart the tractor, and operate the hydraulic remote for Valve 4 to ensure the anomaly does not return.

Parts you might need

(2)
  • Electrodistributor Module / Hydraulic Remote Control Valve (Valve 4 / A105-4)

    00 1164 149 0

    When replacing an electrodistributor valve on the CAN bus network, the new valve may require calibration or configuration via the CLAAS diagnostic tool (CDS) so the HYD (A60) module recognizes it on the network.

  • Electrodistributor Module / Hydraulic Remote Control Valve (Valve 4 / A105-4)

    00 1164 150 0

    When replacing an electrodistributor valve on the CAN bus network, the new valve may require calibration or configuration via the CLAAS diagnostic tool (CDS) so the HYD (A60) module recognizes it on the network.